Home |
Component | Operates | Comment |
---|---|---|
+15 Vdc out of power supply | Yes | |
+5 Vdc out of power supply | Yes | |
Other voltage sources | No | For this, the 5151 requires an incoming horizontal sync signal. |
Vertical stage | Yes | Free runs if no incoming vertical sync signal. |
Horizonal stage | No | For this, the 5151 requires an incoming horizontal sync signal. |
CRT filament (cathode heater) | Yes | Uses 15 Vdc out of power supply. Diagram here. |
14 KV generation for CRT | No | For this, the 5151 requires an incoming horizontal sync signal. |
WARNING: Opening the 5151 will expose you to dangerous voltages and currents. Those threats can still be present long after power has been disconnected from the 5151. Before opening the 5151, adequately educate yourself as to the hazards. Some hazard examples at here. |