AST RESEARCH, INC. TECHNICAL BULLETIN # 1701 04/08/97 TITLE: Bravo MS and DPT 2044W SCSI Adapter ISSUE The Bravo MS may indicate a resource conflict when installing a DPT 2044W SCSI adapter. The system assigns IRQ 15 to the DPT 2044W SCSI adapter, which conflicts with the secondary IDE controller. This issue affects the following systems: 501951, 501952, 501954, 501955, 501956, 501972, and 503043. BACKGROUND N/A ACTION Upgrade to BIOS version 1.04 (AST part number 905579-038) or later. File 05579038.EXE is available from any of AST's On-Line! services as follows: AST WWW Site: http://www.ast.com AST On-Line! BBS*: See IB0001.TXT CompuServe: GO: ASTFORUM Prodigy: JUMP: ASTSUPPORT For additional information on the Bravo MS-T BIOS, see Software Bulletin # 0285, on any of AST's On'Line! services. NOTES N/A TAN 002053PH --------------------------------------------------------------------- The information in this data sheet is subject to change without notice. AST Research, Inc. shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This material contains information protected by copyright. No part of this material may be reproduced in any form without prior written consent from AST Research, Inc. All rights reserved. --------------------------------------------------------------------- Revision 01