AST RESEARCH, INC. TECHNICAL BULLETIN # 1572 09/18/96 TITLE: Ascentia P, Motion Pixels, Video SUMMARY The Ascentia P system may experience only 50% view on the LCD panel. This issue affects all Ascentia P systems. ISSUE When running Motion Pixels' Test or Demonstration software, the display is shifted to the left and only 50% of the picture is seen. A reboot is required to recover. This issue affects all Ascentia P systems. BACKGROUND The Ascentia P system BIOS, version 1.01, AST part number 905584-032 or lower, may exhibit this issue. ACTION Update the Ascentia P system BIOS to version 1.02, AST part number 905584-033 or higher. File 05584033.EXE is available from one of AST's On-Line! services as follows: AST WWW Site: http://www.ast.com AST On-Line! BBS*: See IB0001.TXT CompuServe: GO: ASTFORUM Prodigy: Jump: astsupport * Refer to IB0001.TXT for a list of AST's nternational BBS numbers. To decompress this file, create a temporary directory on your hard drive, copy the downloaded file to that directory, and run the file. For additional information, see Software Bulletin # 0295 on any of AST's On-Line! Services. NOTES N/A TAN 002433AC --------------------------------------------------------------------- The information in this data sheet is subject to change without notice. AST Research, Inc. shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This material contains information protected by copyright. No part of this material may be reproduced in any form without prior written consent from AST Research, Inc. All rights reserved. ---------------------------------------------------------------------