AST RESEARCH, INC. TECHNICAL BULLETIN # 1194 5-25-95
=
BRAVO NB-RC 4/33 MONO9 SERIAL MOUSE DOES NOT FUNCTION PROPERLY
PROBLEM
The Bravo NB-RC 4/33 MONO9 system serial mouse (Microsoft Serial-P2 compatible
mouse) may not function properly. The cursor may not move when the mouse is
moved, or it moves too slowly. Sometimes the mouse may not release or open
applications in Windows.
CAUSE
The system is using a BIOS prior to release 1.03.
SYSTEMS AFFECTED
AST PART NUMBER AND DESCRIPTION
501595-XXX BRAVO NB-RC 4/33 MONO9
SOLUTION
Upgrade the system with BIOS release 1.03 or higher. Request AST part
number 905563-031 from the following:
Contact the nearest AST Authorized Service Center.
Call AST Spare Parts at (800) 727-1278.
Download file 05563031.EXE from AST's BBS.
File 05563031.EXE can be found on AST's BBS (817) 230-6850, in the "Systems"
file area. AST's BBS supports modem speeds up to 28.8k bps.
The above file will also be posted on:
CompuServe
Go ASTSUPPORT
AST Worldwide Web Site
http://www.ast.com