HP OMNIBOOK 600C AND 600CT NOTEBOOK PCS - CONFIGURATION FILES FOR THE
XIRCOM CEM2 ETHERNET-MODEM COMBO PC CARD
NOTE:The products listed are not products of
the Hewlett-Packard Company, but rather
products of third party developers.
Such products have not been fully tested
and only partially evaluated by HP, and
are not endorsed, warranted, or
supported by HP. HP expressly
disclaims all responsibility and
liability for the manufacturing,
distribution, marketing, licensing,
installation, use performance,
maintenance, and support of such
products. Readers of this guide are
advised to make their own independent
verification of the information provided
for such products by third party
developers.
OB600 LAN CARD CONFIGURATION FILES
The following contains the configuration information for the
Xircom CEM2 LAN card for NDIS and Novell LAN Network Operating
System.
Changes to the standard configuration are highlighted in bold.
NOVELL
******* CONFIG.SYS
REM
REM CONFIG.SYS -- OmniBook default startup file for drive C
REM
[menu]
menuitem=LapLink, Windows & LapLink -- Default
menuitem=Windows, Windows only
menuitem=MS-DOS, MS-DOS only
menudefault=LapLink,5
menucolor=2
[LapLink]
[Windows]
[MS-DOS]
[common]
shell=c:\command.com /p /e:1024 c:\
device=c:\dos\himem.sys /machine:2
REM "X=" reserves memory for PCMCIA cards
REM "I=" reserves remaining memory for UMBs
device=c:\dos\emm386.exe noems i=b000-b7ff i=c000-d3ff x=d400-e7ff
dos=high,umb
devicehigh=c:\dos\power.exe
REM OmniBook Socket Services 2.1 driver required for card slot
support
devicehigh=c:\cardsoft\obss.exe
REM Card Services 2.1 driver required for card slot support
devicehigh=c:\cardsoft\cs.exe /systemsoft1=1
REM Card Services APM support required for card slot support
install=c:\cardsoft\cs_apm.exe
REM Initial resource allocator required for card slot support
device=c:\cardsoft\csalloc.exe
REM ATA card driver required for ATA cards
devicehigh=c:\cardsoft\atadrv.exe /s:2
REM Driver required for RAM cards
devicehigh=c:\cardsoft\mtsram.exe
REM Memory card driver required for all memory cards
REM If this driver not installed, remove /s:2 from the ATA card
driver line
devicehigh=c:\cardsoft\mtddrv.exe
device=c:\cem2\odi\cxcfg.exe driver=odi
REM Card identification driver required for cards other than
memory cards
devicehigh=c:\cardsoft\cardid.exe
REM OBMGM must be installed for the system to operate properly...
install=c:\omnibook\obmgm.com
buffers=10,0
files=30
REM LASTDRIVE=Y leaves one drive letter available for Novell
networks...
lastdrive=Y
FCBS=4,0
REM OmniBook needs at least 12 stacks available...
stacks=12,256
REM IFSHLP is required by Windows for Workgroups
device=c:\windows\ifshlp.sys
*** AUTOEXEC.BAT
@echo off
rem
rem AUTOEXEC.BAT -- OmniBook default startup file for drive C.
rem
path c:\;c:\windows;c:\dos;c:\mouse;c:\omnibook;c:\tsi
prompt $p$g
set temp=c:\windows\temp
set tmp=c:\windows\temp
set mouse=c:\mouse
rem To install the MS-DOS mouse driver, remove the "rem" from the
rem mouse command line.
rem c:\mouse\gmouse.com
goto %config%
rem Drivers loaded when undocked.
:Default
goto End
rem Drivers loaded when docked.
:Docked
c:\dos\mscdex.exe /d:aspicd0 /m:12
goto End
:End
c:\windows\smartdrv.exe 2048 128
llra1
c:\windows\net start (note:optional for WFW support)
rem win
c:\nwclient\lsl
c:\xircom\cem2\odi\cem2odi
c:\nwclient\ipxodi
c:\windows\odihlp.exe (note:optional for WFW support)
c:\nwclient\netx
etc.
****NET.CFG
link driver cem2odi
frame ethernet_802.2
frame ethernet_II
int 11
port 320
mem d4000
COM4
comirq 3
nomapi
wordsize 8
** PROTOCAL.INI (OPTIONAL FOR WFW SUPPORT)
[network.setup]
version=0x3110
netcard=XIRC$ODI,1,XIRC$ODI,4
transport=ms$nwlinknb,NWLINK
transport=ms$netbeui,NETBEUI
lana0=XIRC$ODI,1,ms$netbeui
lana1=XIRC$ODI,1,ms$nwlinknb
[net.cfg]
PATH=c:\XIRCOM\CE2\NET.CFG
[XIRC$ODI]
[Link Driver CE2ODI]
data=Frame Ethernet_SNAP
data=Frame Ethernet_II
data=Frame Ethernet_802.3
[NWLINK]
BINDINGS=CE2ODI
[NETBEUI]
BINDINGS=CE2ODI
LANABASE=0
SESSIONS=10
NCBS=12
NDIS
***** CONFIG.SYS
REM
REM CONFIG.SYS -- OmniBook default startup file for drive C
REM
[menu]
menuitem=LapLink, Windows & LapLink -- Default
menuitem=Windows, Windows only
menuitem=MS-DOS, MS-DOS only
menudefault=LapLink,5
menucolor=2
[LapLink]
[Windows]
[MS-DOS]
[common]
shell=c:\command.com /p /e:1024 c:\
device=c:\dos\himem.sys /machine:2
REM "X=" reserves memory for PCMCIA cards
REM "I=" reserves remaining memory for UMBs
device=c:\dos\emm386.exe noems i=b000-b7ff i=c000-d3ff x=d400-e7ff
dos=high,umb
devicehigh=c:\dos\power.exe
REM OmniBook Socket Services 2.1 driver required for card slot
support
devicehigh=c:\cardsoft\obss.exe
REM Card Services 2.1 driver required for card slot support
devicehigh=c:\cardsoft\cs.exe /systemsoft1=1
REM Card Services APM support required for card slot support
install=c:\cardsoft\cs_apm.exe
REM Initial resource allocator required for card slot support
device=c:\cardsoft\csalloc.exe
REM ATA card driver required for ATA cards
devicehigh=c:\cardsoft\atadrv.exe /s:2
REM Driver required for RAM cards
devicehigh=c:\cardsoft\mtsram.exe
REM Memory card driver required for all memory cards
REM If this driver not installed, remove /s:2 from the ATA card
driver line
devicehigh=c:\cardsoft\mtddrv.exe
device=c:\xircom\cem2\cxcfg.exe
REM Card identification driver required for cards other than
memory cards
devicehigh=c:\cardsoft\cardid.exe
REM OBMGM must be installed for the system to operate properly...
install=c:\omnibook\obmgm.com
buffers=10,0
files=30
REM LASTDRIVE=Y leaves one drive letter available for Novell
networks...
lastdrive=Y
FCBS=4,0
REM OmniBook needs at least 12 stacks available...
stacks=12,256
REM IFSHLP is required by Windows for Workgroups
device=c:\windows\ifshlp.sys
***** AUTOEXEC.BAT
@echo off
rem
rem AUTOEXEC.BAT -- OmniBook default startup file for drive C.
rem
net start
c:\dos\smartdrv.exe 1024 128
path=c:\;c:\windows;c:\dos;c:\mouse;c:\omnibook;c:\tsi
prompt $p$g
set temp=c:\windows\temp
set tmp=c:\windows\temp
set mouse=c:\mouse
rem To install the MS-DOS mouse driver, remove the "rem" from the
rem obmouse command line.
rem c:\mouse\obmouse
rem If your DOS mouse application doesn't work, try removing the
rem "rem" from the ENHMOUSE command line.
rem c:\mouse\enhmouse
goto %config%
:LapLink
llra1
rem llra2
rem llra3
win
goto End
:Windows
win
goto End
:MS-DOS
goto End
:End
***** PROTOCOL.INI
[network.setup]
version=0x3110
netcard=XIRCMAC,1,XIRCMAC,1
transport=ms$ndishlp,MS$NDISHLP
transport=ms$netbeui,NETBEUI
lana0=XIRCMAC,1,ms$netbeui
lana1=XIRCMAC,1,ms$ndishlp
[protman]
DriverName=PROTMAN$
PRIORITY=MS$NDISHLP
[XIRCMAC]
DriverName=XIRCOM$
INT=11
IOADDRESS=0x320
MEM=0xD8000
TXBUFFERSIZE=16
COM4
nomapi
WORDSIZE=8
[MS$NDISHLP]
DriverName=ndishlp$
BINDINGS=XIRCMAC
[NETBEUI]
DriverName=netbeui$
SESSIONS=10
NCBS=12
BINDINGS=XIRCMAC
LANABASE=0
************ END of Xircom CEM2 configuration file
****************
Copyright Hewlett-Packard Co. 1996
This information is subject to change without notice and
is provided "as is" with no warranty.
Hewlett-Packard shall not be liable for any direct,
indirect, special, incidental or consequential damages
in connection with the use of this material.
|