PCA Layout All configurations marked "*" are default settingsTerminal Connector CN4
ID2 | ID1 | ID0 | SCSI ID |
---|---|---|---|
OPEN | OPEN | OPEN | 0 |
OPEN | OPEN | SHORT | 1 |
OPEN | SHORT | OPEN | 2 |
OPEN | SHORT | SHORT | 3 |
SHORT | OPEN | OPEN | 4 |
SHORT | OPEN | SHORT | 5 |
SHORT | SHORT | OPEN | 6 |
SHORT* | SHORT* | SHORT* | 7 |
Spindle motor control A SHORT* Auto Start on power up OPEN Controlled by START/STOP UNIT command SCSI Bus Parity checking P SHORT* Enabled OPEN Disabled Offline Self-diagnostics D SHORT* Normal OPEN ExecuteTerminal Connector CN7
Spindle Sync I/O pulse.Terminal Connector CN20Master & Slave control determining whether to receive or transmit SPSYNC are set by MODE SELECT command. This terminal SY Pin1 GROUND Pin2 SPSYNC
External Reset.
This would normally be connected to a momentary switch which would short pin 3 to ground for the reset of the drive and SCSI bus. Normally used for debug purposes only.
R SHORT* External reset signal when connected to ground OPEN No connectionWrite protection WP SHORT* Disabled OPEN Enabled
Termination of SCSI bus TM SHORT* Enable terminating resistor OPEN Disable terminating resistor
External LED connector Pin1 LED(V) Pin2 -LED
to the table of comments!!