CP31370 Baja SCSI
Customer options

SCSI Bus Address
There are three jumpers available for configuration of SCSI ID: E1, E2 and E3. The following table defines the settings:

(The table on this page requires NETSCAPE version 1.1 or later for proper viewing.)

SCSI Bus Addresses*
E1/0E1E2/0E2E3/0E3SCSI ID
OUT OUTOUT O
INOUT OUT 1
OUTINOUT2
IN IN OUT 3
OUT OUTIN 4
IN OUTIN 5
OUT IN IN 6
IN IN IN 7

*Use either but not both: E1 to E3 or 0E1 to 0E3. The 0E header is not installed on drive configurations with an LED on the PCBA.

Disable Spin: A jumper in the E4 location disables spin up on power-on. Disabling spin up on application of power can also be enabled by settting the DSPN bit in MODE SELECT page 0.

E4 Disable Spin on Power on
E5 Terminators on 0E5

J4
1 +12 V
2 Ground
3 Ground
4 +5V

Mounting Holes
Side: 6-32 UNC-2B .15 Max. Insertion
Bottom: 6-32 UNC-2B .25Max. Insertion