CP2124
Customer Options

The CP2124 drive is designed to operate either as a Master drive (C drive) or a Slave drive (D drive). This feature is dependent on two drive settings; the status of hardware Jumper M/S and the firmware setting of a feature bit. When (M/S) is closed, and the feature bit is set, the drive will assume the role of a Master drive. When (M/S) is open, and the feature bit reset, the drive will act as the Slave. In single drive configurations, M/S must remain in the closed position.



(The table on this page requires NETSCAPE version 1.1 or later for proper viewing.)

CMOS Drive Parameters
Cylinders762
Heads8
Sectors39
Precomp0
Landing Zone762

Mounting Holes
Side: 3mmx0.5mm THD4x) 4mm Max. Insertion
Bottom: 3mmx0.5 THD (4x) 4mm Max. Insertion